HomeMy WebLinkAboutSFRA2018-4657 DEC 14 2018 el
DATEOF PERMIT#:
BUILDING PERMIT APPLICATION
(PLEASE PRINT LEGIBLY—COMPLETE ENTIRE FORM)
JOB ADDRESS: 3302 Clearfield Drive,Grapevine,TX 76051
SUITE #
LOT: 3oR BLOCK: 10 SUBDIVISION: COUNTRYSIDE ESTATES ADDITION
BUILDING CONTRACTOR(company name): Marc Jones Construction,LLC/Sunpro Solar
CURRENT MAILING ADDRESS: 12011 Denton Dr
CITY/STATE/ZIP: Dallas,TX 75234 PH:# 4694050991 Fax#
PROPERTY OWNER: Lenny ROIIISpn
CURRENT MAILING ADDRESS: 3302 Clearfield Drive
CITY/STATE/ZIP: Grapevine,TX 76051 PHONE NUMBER: 6175010139
PROJECT VALUE: S 8� °-- .3�(m `7& FIRE SPRINKLERED? YES NO
WHAT TRADES WILL BE NEEDED?(Check ones that apply)ELECTRIC X PLUMBING— MECHANICAL—
DESCRIPTION OF WORK TO BE DONE: Installation of roof mounted solar panels
USE OF BUILDING OR STRUCTURE: Residential
NAME OF BUSINESS:
Total Square Footage under roof: Square Footage of alteration/addition:
❑ I hereby certify that plans have been reviewed and the building will be inspected by a certified energy code inspector in accordance with
State Law. Plan review and inspection documentation shall be made available to the Building Department(required for new buildings,
alterations and additions)
❑ 1 hereby certify that plans have been submitted to the Texas Department of Licensing and Regulation for Accessibility Review.
Control Number: (Not required for 1&2 family dwellings)
❑ I hereby certify that an asbestos survey has been conducted for this structure in accordance with the regulatory requirements of the Texas
Department of Health.
(REQUIRED FOR DEMOLITIONS,ADDITIONS AND OR ALTERATION TO COMMERCIAL AND PUBLIC BUILDINGS)
I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by
the Building Department and in compliance with the City Of Grapevine Ordinance regulating construction. It is understood that the issuance of
this permit does not grant or authorize any violation of any code or ordinance of the City Of Grapevine. I FURTHERMORE UNDERSTAND
THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY,AND THAT THE
DESIGN PROFESSIONAL/OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROVAL FROM THE APPROPRIATE STATE AND
OR FEDERAL AGENCY(S).
PRINT NAME: Sinni Pawar SIGNATURE
PHONE#: 4694050991 EMAIL:
❑ CHECK BOX IF PREFERRED TO BE CONTACTED BY E-MAIL
THE FOLLOWING IS TO BE COMPLETED BY THE BUILDING INSPECTION DEPARTMENT
Construction Type: %4G Permit Valuation: $ 3 1676• c1V Setbacks Approval to Issue
Occupancy Group: •I2,S I lJ Fire Sprinkler: YES -- NO — Front: _ Electrical {--
Division: Building Depth: Left:
Plumbing =—
Zoning: R. 7• Building Width: Rear: — Mechanical —
Occupancy Load: Right: —
Plan Review Approval: Date:l2•'Z I I Y Building Permit Fee:
Site Plan Approval: Date: Plan Review Fee:
Fire Department: Date: Lot Drainage Fee:
Public Works Department: Date: Sewer Availability Rate:
Health Department: Date: Water Availability Rate:
Approved for Permit: Date: 21.1 V Total Fees:
Lot Drainage Submitted: Approved: Total Amount Due: �S
KO.BOX 95104,GRAPEVINE,TX 98099(817)410.3165 O:FORMSOSPERMITAPPLICATIONS V02-Rev.11104,5 BV07,11W,4H1
V DEC � +� �01$ Issue Date:
' " ° ` CITY OF GRAPEVINE
(CIRCLE ONE)
MECHANICAL - ELECTRICAL - PLUMBING - IRRIGATION - FUEL GAS
PERMIT APPLICATION
PLEASE PRINT LEGIBLY-COMPLETE ENTIRE FORM
PERMIT# ( BLDG.PERMIT# — DATE:
JOB ADDRESS: ^,� C1 �;.� ' ,;1 f� SUITE#
DESCRIPTION OF WORK:
a ?&f) \s
PROPERTY OWNER: CgNTRACTING COMPANY: I
� � ( �1S Ma(c ' J,1 ) t��T O l LLC
ADDRESS: ADDRESS:
3�Oz i'
CITYISTATE/ZIP: O�5 CITVISTATE/ZIP:
PHONE NUMBER: 1 PHONE NUMBER:
TYPE OF OCCUPANCY BUILDING AREA PERMIT FEES AMOUNT DUE
SO FT
EACH TRADE
I. R-3
1 - 749 $ 33.25
SINGLE FAMILY, DUPLEX 750- 1,199 $ 49.88
TOWNHOUSE, 1,200- 1,500 $ 63.18
NEW CONSTRUCTION& 1,501 - 1,750 $ 76.48
ADDITIONS(PER UNIT) 1,751 - 2,000 $ 83.13
2,001 - 2,250 $ 89.78
TOTAL SO. FOOT UNDER 2,251 - 3,000 $ 96.43
ROOF 3,001 - 3,500 $ 103.08
3,501 - 4,000 $ 109.73 $ -0/-ggn
4,001 + $ 120.37
EACH TRADE
II. A, E, I, R-1
1 - 500 $ 37.00
HOTELS,APARTMENTS, 501 -100,000 $ 17.50+.035 PER
DRINKING/DINING, 100,001 -500,000 $ 3,500.00+.03 SQUARE
EDUCATIONAL,ASSEMBLY, 500,001 + $15,000.00+.02 FOOT $
INSTITUTIONAL
EACH TRADE
III. B, F, H, M, S, U
OFFICE, RETAIL, WHOLESALE, 1 - 500 $ 37.00
GARAGES, FACTORIES, 501 - 50,000 $ 32.00+ .01 PER
WORKSHOPS, SERVICE 50,001- 100,000 $ 182.00+ .007 SQUARE
STATIONS, WAREHOUSE 100,001+ $ 582.00+ .003 1 FOOT $
CONTRACT EACH TRADE
IV. ANY OCCUPANCY GROUP VALUATION OF
WORK
FINISH-OUTS,
SHELL COMPLETIONS, 0- 500 $ 37.00
ALTERATIONS OR 501- 1,500 $ 45.00
STAND ALONE PERMITS 1,501- 3,000 $ 57.00
3,001- 5,000 $ 72.00
CONTRACT VALUATION OF WORK: 5,001- 50,000 $ 27.00+ .009
IS
50,001- 100,000 $ 127.00+ .007 PER
$ 500 . 100,001-500,000 $ 327.00+ .005 DOLLAR $ _
500,001+ $ 1,327.00+ .003 IVALUATION
EACH TRADE
V. MISCELLANEOUS
IRRIGATION SYSTEMS $ 37.00
MOBILE HOME SERVICE $ 37.00
TEMPORARY POLE SERVICE $ 37.00
SWIMMING POOLS $ 37.00
SIGN ELECTRIC $ 37.00 $
c:%users\sbafte%AppC)ata\Local\Miclosoft\W indm\Temporary Internet Files\CcntenLGuOook\G80E6GOF\MEP APPLICATION 4-1 Ltloc
PLAN SUBMITTAL:
WHEN PLANS ARE REQUIRED BY CODES, ORDINANCES, OR AS DETERMINED BY THE BUILDING
OFFICIAL, THREE (3) SETS OF PLANS SHALL BE SUBMITTED IN HARD COPY FORMAT. ENGINEER SEALED
PLANS AND CALCULATIONS SHALL BE SUBMITTED AS REQUIRED BY CODES, ORDINANCES OR WHERE
OTHERWISE REQUIRED BY STATE LAW.
OTHER INSPECTIONS AND FEES:
• INSPECTIONS OUTSIDE NORMAL BUSINESS HOURS(2HR MINIMUM)...............................................$42.00/HOUR*
• REINSPECTION FEES....................... .................. ......_............................................................... $42.00
• PERMITS FOR WHICH NO FEE IS SPECIFICALLY INDICATED........................................................... $3T00
• INSPECTIONS FOR WHICH NO FEE IS SPECIFICALLY INDICATED (1/2 HOUR MINIMUM)......................$42.00/HOUR
• ADDITIONAL PLAN REVIEW REQUIRED BY CHANGES,ADDITIONS, OR REVISIONS TO
APPROVEDPLANS.......................................................................................................................$42.00/HOUR
• BUILDING PERMIT FEES FOR THE GRAPEVINE-COLLEYVILLE INDEPENDENT SCHOOL DISTRICT
SHALL BE 25%OF THE FEES ESTABLISHED IN THIS TABLE
• FOR USE OF OUTSIDE CONSULTANTS FOR PLAN CHECKING AND INSPECTIONS, OR BOTH.........ACTUAL COSTS**
I HEREBY CERTIFY THAT THE FOREGOING IS CORRECT TO THE BEST OF MY KNOWLEDGE AND ALL WORK WILL BE
PERFORMED ACCORDING TO THE DOCUMENTS APPROVED BY THE BUILDING DEPARTMENT AND IN COMPLIANCE
WITH THE CITY OF GRAPEVINE CODES REGULATING CONSTRUCTION. IT IS UNDERSTOOD THAT THE ISSUANCE OF
THIS PERMIT DOES NOT GRANT OR AUTHORIZE ANY VIOLATION OF ANY CODE OR ORDINANCE OF THE CITY OF
GRAPEVINE.
I FURTHER CERTIFY THAT ALL WORK THAT IS REQUIRED TO COMPLY WITH ANY FEDERAL, STATE, AND / OR
LOCAL LAW REGARDING ENERGY CONSERVATION WILL BE PERFORMED IN ACCORDANCE WITH THOSE LAWS,
AND THAT VERIFICATIO OF ENERGY CODE COMPLIANCE SHALL BE SUBMITTED TO THE CITY UPON REQUEST.
SIGNATURE OF COM C OR OR AUTHORIZED AGENT PRINTED NAME
(OR HOMEOWNER FOR HOMEOWNERS PERMITS)
PHONE 4os) -oc"\ EMAIL: ��
*OR THE TOTAL HOURLY COST TO THE JURISDICTION WHICHEVER IS GREATER.
**ACTUAL COSTS INCLUDE ADMINISTRATIVE AND OVERHEAD COSTS.
Development Services Department,Building Inspections
The City of Grapevine CIE P.O.Box 95104*Grapevine,Texas 76099 *(817)410-3165
Fax(817)410-3012 CIF www.grapevinetexas.gov
C\Users\sbatte\AppData\Local\Microsoft\Windows\Temporary Internet Files\Content Out wk\G60E6GOF\MEP APPLICATION 4-11.doc
Data Sheet
Enphase Microinverters
Region:US
Enphase The high-powered smart grid-ready
Enphase IQ 7 Micro"" and Enphase IQ 7+ Micro-
IQ 7 and IQ 7+ dramatically simplify the installation process while
achieving the highest system efficiency.
Microinverters Part of the Enphase IQ System,the IQ 7 and
IQ 7+ Microinverters integrate seamlessly with
the Enphase IQ Envoy", Enphase Q Aggregator'",
Enphase IQ Battery", and the Enphase Enlighten'"
monitoring and analysis software.
IQ Series Microinverters extend the reliability
standards set forth by previous generations and
undergo over a million hours of power-on testing,
enabling Enphase to provide an industry-leading
warranty of up to 25 years.
Easy to Install
• Lightweight and simple
• Faster installation with improved,lighter two-wire cabling
• Built-in rapid shutdown compliant(NEC 2014&2017)
Productive and Reliable
• Optimized for high powered 60-cell and 72-cell*modules
• More than a million hours of testing
• Class II double-insulated enclosure
ILL listed
Smart Grid Ready
• Complies with advanced grid support,voltage and
frequency ride-through requirements
• Remotely updates to respond to changing
grid requirements
• Configurable for varying grid profiles
• Meets CA Rule 21 (UL 1741-SA)
UL 'The IQ 7+Micro is required to support 72-cell modules.
To learn more about Enphase offerings,visit enphase.com n E N P H AS E
Enphase IQ 7 and IQ 7+ Microinverters
INPUT DATA(DC) IQ7-60-2-US IQ7PLUS-72-2-US
Commonly used module pairings' 235 W-350 W+ 235W-440 W+
Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules
Maximum input DC voltage 48 V 60 V
Peak power tracking voltage 27 V-37 V 27 V-45 V
Operating range 16 V-48 V 16 V-60 V
Min/Max start voltage 22 V/48 V 22 V/60 V
Max DC short circuit current(module Isc) 15 A 15 A
Overvoltage class DC port 11 II
DC port backfeed current 0 A 0 A
PV array configuration 1 x 1 ungrounded array;No additional DC side protection required;
AC side protection requires max 20A per branch circuit
OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter
Peak output power 250 VA 295 VA
Maximum continuous output power 240 VA 290 VA
Nominal(L-L)voltage/large' 240 V/ 208 V/ 240 V/ 208 V/
211-264 V 183-229 V 211.264 V 183.229 V
Maximum continuous output current 1.0 A 1.15 A 1.21 A 1.39 A
Nominal frequency 60 Hz 60 Hz
Extended frequency range 47-68 Hz 47-68 Hz
AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms
Maximum units per 20 A(L-L)branch circuit- 16(240 VAC) 13(240 VAC)
13(208 VAC) 11 (208 VAC)
Overvoltage class AC port III III
AC port backfeed current D A 0 A
Power factor setting 1.0 1.0
Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading...0.7 lagging
EFFICIENCY @240 V @208 V @240 V @208 V
Peak CEC efficiency 97.6% 97.6% 97.5% 97.3%
CEC weighted efficiency 97.0% 97.0% 97.0% 97.0%
MECHANICAL DATA 10 7 Microinverter
Ambient temperature range -40°C to+65-C
Relative humidity range 4%to 100%(condensing)
Connector type MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter)
Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket)
Weight 1.08leg(2.38Ibs)
Cooling Natural convection-No fans
Approved for wet locations Yes
Pollution degree PD3
Enclosure Class II double-insulated,corrosion resistant polymeric enclosure
Environmental category/UV exposure rating NEMA Type 6/outdoor
FEATURES
Communication Power Line Communication(PLC)
Monitoring Enlighten Manager and MyEnlighten monitoring options.
Both options require installation of an Enphase IQ Envoy.
Disconnecting means The AC and DC connectors have been evaluated and approved byUL for use as the load-break
disconnect required by NEC 690.
Compliance CA Rule 21 (UL 1741-SA)
UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B,
CAN/CSA-C22.2 NO.107.1-01
This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and
NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC
and DC conductors,when installed according manufacturer's instructions.
1.No enforced DC/AC ratio.See the compatibility calculator at hops'//enphase com/en-us/support/module-compatibility
2.Nominal voltage range can be extended beyond nominal if required by the utility.
3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area.
To learn more about Enphase offerings,visit enphase.com v E N P H AS E
0 2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc.
2018-02-DO
r
W v
0
G' o O y
W ` C a
O. 2 p s
Co > U) E
G Q CD a
A �. N
�U
0
r
Q
.41 M-
IT
If
w
�ygyp � ��]E@yS^ Ey �yyg �a 4 � o )y Q rsg
� gY
F
o p ag gg �
AL
sg r' < r E $ Oil S
Cw `
Y
u + 3 A
CL
vi
G «SS J N 'amp `O J I m
N
N —p m 4• � � i
O p'S C J
Q � m � m " 6iC GI aJJ: z Ia JJ
U d y
Cl) E g $
p S O @ N § 8 G
a
cx 0 E
agR � g . . � wa ws
r
+ (n
rl ` in r:) to R s o v o
' � d •• M (D Of � o a b
N C S e— e— w » m ��•. m N D m
y m 1]. Cl) @ b N N O
f0 (7 C vJ b C �G" Vr N o jw
J W 7 0on
N e A m
N N
2 �
W � � Y
ri
c N o 0 0
((� = u u w �p �_ li m
d a s n o 30
cr
W O.
w C ❑.. is � b � �. F �a
T 'J L • U 4 Z5
a_
L
txo
LL
W
� L c E
to
'Cvl
G �
C
_ N
N
� o
m
m o.
m o
o a
a aA
t
� o
N
Q
Q
t].
LL
v I c m
O _ �
� C �
w C !Z n ry
C ❑
0
O
1
V O
Ecz
I�'� 0..
o v c 1 p
s �,`ti��tiltl�tl CA_ _ 11 w
It
U
Y = ram• : z e� Gy, "' ! z U
/ cn
: ? w: z
• � � r
u: o r
3 . lug: • _ :
n ° o . 111111t"�ti rn
LUcz U 6n
.-) v �)
mg
v w cT _o y
w •"' �
a a o � o o d Lv o
ni C7 cn w v
•" = E ' Z Q
Ca z w°, � wo
o s w 0. y
o a�i a cn
co
., _ (n w w O O
rn u. + Z z �
M an Z O �
oo � a O_ wa ¢
C U C d v' « � Z
J > N > U p cC .�.� T U? ® cn p F- dow
Cry 0
*" �T
i O Q o o > b � o o ( � zW c=nL7— > x � ¢ m
s C7 > � '� �!l LIJ Q H 1 d 0 W w 3
ZU o 'er gC �'' w ku> ' az rrmu-�
0. o Cis 3 s B o U s = Q ry Z F� L Z — aw O x
J O Q C� U
W
' Q
r : z • 04 o y
r 00 ''�� �) ono
Q Clu. 2� 1 M
r': o
C; � w
0 Ln
o v o LLJ
CN v 2 , 2 :
C C O d C vi C C C v
r a! .0 Ol i 3 t F m C N *' O i O O O x
aj
y M Y v1 m y O i � E E
a 5 a�i c °c° Q 3 a U o U U U a
,n 0 — m c O O m
� .on a) _' _ - -
n o .� aci Z v o �° c a a' o o o u v
U no -0 as.+ ^ ° °- '�+ 7 00 LDrj 00 00 0o U O 'L C y d' V N N Q W
Q C C UCo = 4�u (U v V Oi 4 d' �' °7� 't- !? c 3 u `� =� = =� = u a
O J y... Q �_ LA Y Y Y Y O V (LC L L m
Qj
Q o M O ) 7 N C [n U C N M vt M v m
o n
c ° - ° c o c
° ° u � `� rri av M lD Ln E o Ln Ln '� a _� N n °' O O w o
L
O_ O E m m lD a1 aJ ate+ ° •i- W a0 W y Q D- O 1 .-� •--1 Q
= a o L L oo O O U v� e-I r-I eiQj O
° i s a LL a th Im m z 0 0 V) m o o 0 Ln o a
coI o o m a v LD m �-
m 0_ob O 7 >x x �p c
t0 Y '> c-I m N l�j N (� �-I .--I �--I 00 > o Ln V1 t/1
U " m ~ m o o n o0 00 00 0 _ v a
u (U u
•0 c t ~ = c c c ? o M a o
a1 L L L 0 ° n 3 D O) m C
3
U°O
OU
01 Yu0 "Y° Co`^ I� n Z Ln •-I „'p>=O Ln 00 00
�m O M M
O 6 oj C (% O N
O N •� N N _C L.L rN-1 eNi N
U a v — v v Q n
co ` * M
C '6 _6 (U $ a
O O
000 i' iii -- °O i o 'i -6 m m O v n n Ln M M
a! N m d 000 Q C .. u -a z 2 Y m M m Ln ON N N O O c-I r i m O
S
3 m c o on o 0 o v a
O O N O U ? W C L O
O u v O w- L L o
> Q Y C a1
iLa.+J E f_ s.. °Q C I—QCfl N0 o 'yu0.,
iW m } .OD O m Y0 ei N� a1 �
r14 c Ma)oWm O W 1-1 N M [t Ln LD NOU a,o 7 (UY N Nc
oOoC N `.
N
p
.➢. .Il\r7 z
OF T�Its
_ BPS............. {q 2t
it,
CITY OF GRAPEVINE
RELEASED FOR CONSTRUCTION
° -- - i HENRY I. DiFRANCO,JR.
......
SHEET: OF: _. _ _ it 9: 1o6!)82
RELEASE DOES NOT AUTHORIZE ANY WORK IN e f
OONFlJCT WITH THE BUILDING CODE OR ZONING ORDINANCE. IIIi
= S/OA�ONAL
CRY APPROVED PLANS TO BE KEPT ON
THE JOB Si,`iE AT ALL TIMES V
DATE: 12 21 20. 1�- BY: o�Y 11/29/18
BUILDING INSPECTION DIVISION:
RELEASE DOES NOT APPLY TO CONSTRUCTION IN
EASEMENTS OR'PUBLIC RIGHT-0F•WAY.
P.L L CHANGES MUST BE APPROWO
® Firm No. F-13180
Principal Engineering, LLC
SOLAR ARRAY. 29 Panels LENNY ROLLISON
_-- - - - - - �WINDSPEED (CAT II): 115 MPH 3302 CLEARFIELD DRIVEGRAPEVINE Tx 76051
BUILDING HEIGHT: 24'-0" Dace Sheet— -
10.25.18 No: 1 of 2
N
o
QrrY OF GRAPEVINE
RELEASED FOR CONSTRUCTION
SHEET:- OF:
RELEASE DOES NOT AUTHORIZE ANY WORK IN
CONFLICT WITH THE BUILDING CODE OR ZONING ORDINANCE.
CITY APPROVED PLANS TO BE KEPT ON
THE JOB SITE AT ALL TIMES
DATEII 17-- 'al - Zolk-- BY: OF r III
BUILDING INSPECTION DIVISION:
RELEASE DOES NOT APPLY TO CONSTRUCTION IN
EASEMENTS OR PUBLIC RIGHT-OF-WAY.
ALL CHANGES MUST BE APPROV17)
.......................... ....
HENRY I. DiF
..........................
?e 106982
0
e*"'CENSf
s 1-........ ra
Firm No. F-13180
Principal Engineering, LLC
1 = RAIL: 14FF LONG LENNY ROLLISON
2 1 RAIL SPLICE: JOIN RAILS TOGETHER W/4-N0.10 X"SCREW(#3) L-FOOT LAYOUT 3302 CLEARFIELD DRIVE
4 R L-FOOT: CONNECTS RAIL TO ROOF, EVERY 4FT @ RAFTERS NOT TO SCALE GRAPEVINE TX 76051
0 CONNECT WITH Ys"BOLT(#5)AND%"NUT(#6)0 RAIL ----7- —---
CONNECT WITH LAG SCREW AND SEALENT @ ROOF Sheet
10.2 5.18 No: 2 of 2
August 6, 2019
Sunpro Solar
12011 Denton Dr.
Dallas, TX 75234
RE: 3302 Clearfield Drive
Dear Applicant:
On December 14, 2018 a building application was submitted to this office for
review for the above referenced address. Our records indicate that your permit
request has expired. If you wish to proceed with this project new applications and
plans must be submitted.
Performing work without a permit is a violation of city ordinance, regardless of
whether or not an application has been made, and could result in the revocation
of your contractor’s registration for a period of not less than one year, and up to a
$2,000.00 fine. Additionally, failure to obtain your permit within 180 days of
application has resulted in the expiration of the permit.
Sincerely,
Connie Cook
Development Services Assistant
Development Services Department
The City of Grapevine P.O. Box 95104 Grapevine, Texas 76099 (817) 410-3165
Fax (817) 410-3012 www.grapevinetexas.gov