HomeMy WebLinkAboutCU2019-28/PD2019-01/Z2019-04 CC ITE-M ft 4, 25, 26, 27, 28 �'Z I T IIE�-IMI ft 4, 7, 8, 9, 10 TO: HONORABLE MAYOR, CITY COUNCIL MEMBERS AND THE PLANNING AND ZONING COMMISSION PROW BRUNO RUIMBELOW', CITY MANAGER SC OTT WILLIAMS, DEVELOPMENT SERVICES DIRECTOR MEETING1 DATE- OCTOBER 15, 20191 SUBJECT: DEVELOPMENT SERVICES TECHNICAL, REPORT OF ZQNE CHANQE APPLICATION Z19-04, _CQ MITI QNAL ., QSE APT QATION QU19-29, AN ELANNED DEVELOEMEN OVERLAY PD19&1 JEFFER59N $HAIRY" ER ---------- - APPLICANT: Miller Sylvan Grapevine 0% Lake 1835 PROPERTY LOCATION AND SIZE, The subject property is located at 431 Scribner Street and is proposed to be platted as Lot 1, Block 1, I ft-jolown Nirport Jefferson Shady Brook Addition, The property contains 14.65 acres and has approximately 530 feet U -I of frontage along Shady Brook Drive and 1,00 feet of frontage,along Scribner Street, REQUESTED ZONE CHANGE, CONDITIONAL USE, AND PLANNED DEVELOPMENT OVERLAY AND COMMENTS- The applicant is requesting a zone change to re one ag2roxiaiftly 12.21 jcresjroM"R- MHi" Manufactumd Home District and 2.44 acres from"R-MF-2"'Multifamilv District to"R:- MF"Mulfifamgy Distrigt for the d'evelgpment of a 362-unit mulftmil The licanty pr(*ct, a__ _h_ 12p is also seeking a conditional use permit to exceed densi!y. reduce the front and setback, increage hgighl, agdfgduce ggrki_ng,—A glanned� develoOMPfIl gygdoy is also being Mgnested to deviate from,but not be limited to reducing the side and setback, increasing the overallOrcentage of units between 600-750,§gcare feet,increasing maximum!building IeMthqpd,,.Aecrea§jng building se "on. It is the applicant's intent to develop a 362-uniit, gated multifamily complex on an 012CLAZ19-04.4,CU19-28,4,PD,19-01.4 October 10,2011 9(1 1-26AM) PZ II'T �_I I t 4, 7, 8, 9, 10 approximate 1 5-acre parcel of land located at the southwest corner of Shady Brook Drive and Scribner Street. This project will have a primary and secondary point of controlled access both from Scribner Street. relative to unit mix, the complex will consist of 198 one bedroom units ranging from 600-97 square feet in size; 134 two-bedroom units ranginig from 1,0 0-1„ 10 s.f.; and 15 three-bedroom units 1, 1b s;f, in, size. Also as part of this project the applicant intends to develop 15 brownstone-style apartments that are three- stories in height ,and resemble a product similar to an attached town,home with incorporated garages on the first floor. These brownstone apartments will consist of six, two-bedroom units 1,349 s.f. in size and nine, three-bedroom units ranging from 1,59,6- 1,799 s,f. in size. The proposed project consists of a total of eleven primary structures with, four specific building types, • Building Type A: the largest structure within the project; four stories in height `5 feet)with a portion of the structure located below grade.This structure contains 166 units, 110 of which are below grade. Immediately adjacent to,the west is a two level garagne level below grade and the second level at grade.. • Building Type B: the project will have two structures of this type for a total of 66 units, three stories in height g feet)with incorporated private garages. • Building Type C: the project will have five structures of this type for a total of 111 units, three stories in height 39 feet)with incorporated private garages.. • wilding Type l : the project will have three structures of this type---the brownstone units, three stories in height (35 feet)with incorporated private garages as part of the first level. The flexible design standards within the conditional use section of the"R- F"Miiulti-Family District allow through the conditional use process consideration for increased density beyond)the 20 dwelling units allowed per acre, increased height in excess of the two-story„ 35 feet maximum as stated in the district as well as a reduction in the front yard setback 40 feet) and a reduction in required parsing (two spaces per unit), With,this request the applicant is proposing a diensity not to exceed 25 dwelling units per acne and a maximum height not to exceed four stories (65 feet) for a portion of Building A. The front yard setback along Scribner Street is proposed to be reduced to 20 feet for all structures with frontage along Scribner Street except for wilding D-lll which will be set back 16 feet. Required parking for the project is 724 spaces the applicant conducted a parking study which recommended a ratio of one space per bedroom(550 total bedrooms)along with a guest parking ratio of 0.20 spaces per unit. With a total 623 spaces recommend by the study, the applicant has provided a total of 642 spaces for a ratio of 1..77 spaces per dwelling unit, Parking will consist of 308 general surface spaces, 106 private garage(tuck- under)spades, and 4 tandem spaces. A two-level parking garage immediately adjacent to Building A to the west willI have g at-grade surface spaces and 94 below-grade span the applicant has also provided 10 on-street spaces along Scribner Street. o.° U''Zl g,04.4, U 1 1-28,4,PDT 11 .01.4 2 toter 10, 019(T4 M) 1, f C IITE-M t 4, 25, 26, 27, 28 �'Z II'T �_I I t 4, 7, 8, 9, 10 i The 'R-MF" Multifamily District regulations require a minimum building separation of bg feet for structures that are arranged face-to-face or back-to-back. The applicant is seeking! a planned development overlay to reduce this separation to 21 feet between Building A4 and -I in, are effort to provide a sense of community and space between the two structures. Building length is limited to 200 feet;the applicant is requesting to not emceed 300, feet for Building A which is the center piece of the development The side yard setback within the "R- F" Multifamily (District is established at 20 feet'. the applicant is requesting a side yard setback of 10 feet for Building C-1 located at the southeast corner of the site to better position the structure relative to the main entrance to the site and its alignment with Peach Street. Lastly„ the applicant is utilizing the planned development overlay to increase the ratio of units within the complex between 600- b0 s.f.to 35 percent of the total number of units; the ordinance limits this ratio to 15 percent. This percentage increase is based on a market demand study and an above average unit size for units within the complex.. Relative to the relocation of the existing residents within the mobile home park, the applicant has partnered with GRACE to put in place a process to assist residents to transition to new Irving accommodations within an approximate six-month period. GRACE has hired a case manager that will help provide as-needled financial assistance and rent relief during this transition period. ,See the attached letter. Contained within your packet is an affidavit of compliance signed and sealed bythe project architect stating the project is in compliance with the adopted Design Standards Manuel for Multifamily and Vertical Mixed Use Development. Although the project is not within any of the five specific districts listed with the design guidelines,the applicant has selected from the 24 (Misted criteria those,standards that are directly applicable to the subject site given its unique aspects such as, location, topography, access, and visibility. The applicant, has included,graphic exhibits that demonstrate compliance with specific elements of the design standards. PRESENT ZONING AND USE; The property is currently Zoned "R-I E-I"' Manufactured Home District and OR-ME- " Multifamily District. That portion of the property zoned"R-MI-l"Manufactured Home District is currently developed as a 72 lot mobile home park, That portion currently zoned"R- F- Multifamily District is currently, undeveloped. HISTORY OF TRACT AND SURROUNDING AREA- The subject property and the property to the north and the southernmost portion of property to the east were zoned "ill Mobile Home District prior to the 1984, City Rezoning. The property to the south and the majority of the property to the east were zoned "R-V Bungle Family District prior to the 1984 City Rezoning.orning. The property to the west was zoned "S-P"Specific Use Permit prior to the 1984 City l e ou~niing. At the,duly 19, 12CU2 N - .4,CU19-28.4,PD19-014 3 October 10,2019(T a) I CC ITE-M ft 4, 25, 26, 27, 28 FIB' I T E_IMI ft 4, 7, 8, 9, 10 2016 meeting the property to the west (111.83 acres,) was rezoned from "R-MF-2" Multifamiilly District and "PRD-1 2" Planned Residential Medium Density District to"R-5 V Zero Lot Line District for the development of 52 residentiail lots but was never developed.A subsequent planned development request(PD 17-05)was considered andl approved at the Jia,nivary 16, 2018 meeting on the property to the west which allowed for 44 residential lots along with an increase in building and impervious coverage along with a reduction in front, rear', and side yard setbacks and a reduction in separation between structures on adjacent lots. SURROUNDING ZONING AND EXISTING LAND USE- NORTH- "GU"'Governmental Use District—City of Grapevine property;GRACE office facilities SOUTH- 'R-MF-1" Multifamily District and "GU" Governmental Use, District— mini-stora:ge warehouse facility-, GCI�SD Middle School property EAST- "GU"Governmental Use District, "R-MF-1"Multifamily District,and"R- 5.0"Zero Lot Line District"-City of Grapevine Service Center;existing single family homes WEST- "R-5.0" Zero Lot Line District, "R-MF-2" Multifamily District and "GU" Governmental Use District--single family residences currently under development', existing multifamily complex- GCIS,D Middle School property AIRPORT IMPACT: The subject tract is not located within any of the noise zones as defined on the"Aircraft Sound Exposure: Dallas/Fort Worth Regional Airport Environs" map. MASTER PLAN APPLICATION: The Master Plan designates that portion of the subject property currently zoned "R-MH" Manufactured Home District between Shady Brook south to Peach Street as an ORM" Residential, Medium Density land use.That portion of the subject property zoned both,"R- MH"Man,ufactured Home District anid"R-MF.2 Multifamily District south of Peach Street is designed as an "RH" Residential, High, Density land use. This multifamily project has a density of 24.7 dwelling units per acre. The land use designation of "RM" Residential, Medium Density was established to accommodate densities between four and twelve dwelling units per acre. Relative to that portion of the subject property with the land use designation of"RM"Residential, Medium Density,the request is not incompliance with the Master Plan, That portion, of the subject property with the land use designation "RH" Residential, High Density is in compliance with the Master Plan. 0AZWQ19-04.4,CU19-28.4,PD19-011 A 4 October,10,2019(745AM) ryll CC ITE-M ft 4, 25, 26, 27, 28 �'Z I T IIE�-ICI ft 4, 7, 8, 9, 10 THOROUGHFARE PLAN APPLICATION- Shady Brook Drive and�,Scribner Street are not designated thoroughfares as shown on the City's Thoroughfare Plan., Scribner Street has a variable width right-of-way with paved street sections varying between 24-28 feet in width. The applicant's traffic impact analysis report suggest improvements w illl be needed at the intersections of Scribner Street/Northwest Highway and Scribner Street/Shady Brook Drive. If the request is approved the applicant will considier further improvements to Scribner Street and possible, cost sharing with the City in a,future development agreement. Yrs 0,,VCUV1 9-04A,CU 1 9-28A,PD1 9-014 5 0doW,10,2019(7:45AM) C C I T E'IMI ft 4 2 11:3 pia �IPZ 1 1]it, t� Ipq Kimley�'*Horn MEMORANDUM To: Bryan Grant JPI Construction 600 Las Colinas BIWE, Irving,TX 75039 From: Hiron Fernando, P.B. Marianna Borrego, EIT Kimley-Horn and Associates, Inc. Registered Firm F-928 Date: August 29,2019 Subject: Grapevine JPI Scribner Grapevine, Texas Parking Demand Analysis of Comparable Multi-,Family Developments Intro duction, Kimley-Horn and Associates. lnc. was retained to conduct a parking study for the JPJ Scribner Development located at Shady Brook Drive and N Scribner Street in Grapevine,TX A site vicinity map is provided as Exhibit I. The study is intended to examine the parking demand in comparable muft'i family development and:, make observations of parking demand from the current land uses, This memorandum documents the line of Inquiry which was investigated to support the City standard of 2.00 spaces per unit parking rate: national research and local observations of perking occupancy at comparable sites, Careful sizing of parking areas to specific uses will prevent the waste of space and building materials that is caused by Providing parking that Is rarely if ever used, Excessive parking also has negative Impacts on often-hidden issues Ike walkable design,storm water runoff,and urban heat island effects. ,Pro osed Deve,loptnent The proposed multifamily development will consist of 362 dwelling units of multi-family apartments with a total of 550 bedrooms.Table I shows the proposed multifamily unit mix.The proposed site Is k>cated at Shady Brook Drive and N Scribner Street,which Is east of State Highway 114 and north,of Northwest Highway in Grapevine,i Texas, Currently, Shady Brook Drive and N Scribner Street are two-lene undivided roads with a posted speed of 30 mph, The proposed parking supply is estimated to be 623 parking spaces using I space per bedroom,andi a guest parking ratio of 01.20 spaces par dwelling unit A site plan is provided as Exhibit 2. ...................................... ............ .................. CC ITEM ft 4, 25, 26, 27, 28 PZ I IIE_I ft 4, 7, 8, 9, 10 Kimley )))Horn Table 1: Proposed Muttifamily Unit Mix moultOW01111 Bedrooms Oommml 1 Bed Units 1_98 1098 2 Bed Units 140 280 3 Bed Units 24 72 36 2 According to the City parking requirements,the parking ratio Is .0 spaces per dwelling uinit. Table 2 shows the total parking spaces required for the proposed 362 dwelling units based on the city parking criteria. Table 2:City Code Parking Requirement ................ Planking Ratio Total Oweliflng UnNs TotW Parking 2 spaces per DU 362 724 . ......... F"arking Research, ITE published Paddng Generation 6M Edflion, a compendium of parking demand research at sites across the country. IT E provides,more Information on each,base parking demand rate than do most other sources, although the number of observations is, still limited. The ITS tracks suburban,, dense mulfi-use,, and central business district differences. The suburban,location is the most suitable for the JPI Scribner DeveIppment.Table 3 shows the average parking demand rates for suburban multifamily uses which are in similar areas to the JPi Scribner Development, Table 3-IT E Parking Generation Demand IT E Land Use ITE a m pew asi ww rra Parking Code Demand par Dw*tjI!Ntlhlt Demand gar ft room 0 Multifamily Housing(Low-Rise) Week 7— Suburban, day 220 111 0.66 ............ Multibmily Wusing(Low-Rise), 220 1,31 Ol,80 Suburban, Saturday Datz Coffection and Local Otmer%eatiorts Kimleyl collected parking occupancy data on Thursday,August 22,,and Saturday,August 24,,2019 between 10 PM and 12 AM. The data was collected at five, different multi-familly apartment developments,located within a 5-mile radius,from the study site.The data collection included vehicles located behind the access-,restnicted gate, which is available for residents only; vehd,as outside the gate,which,is available for visitors and future residents; and parking garages. It should be noted that for this study,each enclosed parking garage is Irestedas an occupied parking space.A couple of sites had trailers, bloats, and portable storage containers at the parking units, which were Included as occupied parking spaces. .......... CC ITEM ft 4, 25, 26, 27, 28 PZ I T IIE�-IMI ft 4, 7, 8, 9, 10 Kimley,,o#Horn Based on the site visit observations, all the study locations had plenty of parking: spaces available, therefore these transportation vehicles and storage units did not interfere with the regular parking operation on the study locations. The average occupancy across the study sites Is effectively above 90% The data collected was conducted at the following apartment locations: 1. Grapevine Station 2 tone"e & Enclave,at Grapevine 4. Terrawood & The Asher As it is shown In Table 4, the weekday parking demand for the five study locations averaged to 1136 vehicles,per dwelling uink, The average number of vehicles per bedroom was equal to 0.914.Table 5 shows the parking demand observed on Saturday equals to 1.34 vehicles per dwelling unh and .94 vehicles per bedroom. All study locations had parking garages available. Several apartments had driveways available at each,parking garage,which residents use as a parking space area.This Instance was counted' as double occupied parking space, which created a conservative high ratio of parked vehicles per unfl. Table 4 and Table 6 provide the number of units and the parking demand at each study location during the weekday and Saturday, Table 4:Weekday Parking Demand C*s*Md PAMOO Demand obser04 r"d L00100", $bAY$40 Dwol""g 1 send (En dand0sraps tact a" Ow""Onopor o9roand pore 1 Gmpeune station I 20AS 300, 343 1.66 1,14 2 312 463 454 148 Ose .......... 3 Endew at GrapeOne 243 391 24,2 1.00 0.62 4 Ten%Wd 291 401 419 1.44 t04 5 Ashw 450 Sol 1.29, .... wx--Nxwlw -1111 -1 - , " i - - -------, Xqtkft"Itp oft RMS I .T vets 'M 301 309 ........... CC ITEM ft 4, 25, 26, 27, 28 PZ I T IIE�-I ft 4, 7, 8, 9, 10 Kimley'>Aiorn Table 6:Saturday Parking Demand d PorNing Depend 010wra rod wrr46*4004 Garagestoctodog) Oon a"site Wits sedmoms — 040"ON I Oardetw per I GMP"rW swim 2W 3W 3113 1,60 1,04 2 31-2 4-63 "----419 ""'--134 0190 .......... 3 Ersdaw at Grape4mi 243 391 330 4 Termwood 291 401 403 1.38 5 Ashef 4W 649 1.22 2.014 TIOIAW _tU 1.34 04 ",jig 30 03 Conclusion The proposed supply will be the development's bedrooms plus a,guest parking ratio of 0.20 spaces per dwelling unit.Based on the parking data collection and field observabons,the proposed parking supply of 623 spaces, (1.72 parking spacers per dwelling unit or 1.13 spaces per bedroom)will provide an appropriate capacity to meet the parking demand for the proposed,multilfamily development. According to fTIE parking average rates, 474 spaces meet the parking criteria for the 362 units (550 bedrooms), The observed demand shows a total of 617 parkingi spaces. Therefore, by applying a conservative,parking ratio per dwelling unit,the proposed supply*11 provide a satisfactory amount of parking spaces, These results show that the actual parking demand is comfortably below the City standard of 2,0 spaces per unit. Table 6 shows a summary of the parking analysis for tare proposed multifamily development Table 6:Paddnig,Analysis Summary .............. SOW" Pandas ftdoMwotllaq UhIt tea ROVOW1*0" woakdav $8UMUY so ss�reomq cay paddag Requimment 2.OD 724 474 ITE,AW"e PA9 1,21 111 0,66 Mowed Demand 13l 1,34 044 0,94 517 —------------ Pmpmed Supp y 1,72 1113 623 .......... j END, Attached: * Exhibit 1 Vicinity Map * Exhibit 2-Site Plan * Parking Count Data Summary Table 1 n CC II'TIEICI t 4, 25, 26, 27, 2 u � 0 �I iVV ff it III " � I f � r 5 �i f iy 9� m +v oiq� 1 FHA t f r of Al CC ITEM ft 4, 25, 26, 27, 28 PZ I T IIE IMI ft 4, 7, 8, 9, 1aP ................. arm x HIM, pr al E CII II-ICI t 4, 2 , 26, 27, 2 PZ II T _I I t 4, 7, 8, 9, 10 i Klmley ,,>>Horn a Parking Couirdt Data Sp ry fiable _ mis 4N p mw �arw Tsui Itall Dw4wlplwylUkwldw mw4lrwowrw „ IIw4wM44ww a►wiwdww �wawr4l wprrwwd aawwwxwne4h Idbaww4N udau Ii PON"mawmd I,wmomae p Pwoxv,ae wwmw! per tlrallwww�www ��.� a3w 34S 3'I3 1 Ob tso 1,04 I'M Twwary Tr �wapawd4r�Iigw ! i I Iloy .,.,... _ . ....... �4wGwk wI wtiw Y 23 1 1'WA4 Omp"iepw wIIGw =6 MapmAry MddEw IIhd 4w 'ft Asher I f