Loading...
HomeMy WebLinkAboutNSFR2018-1675 ENVIRONMENTS FOR t' SITE ID:423845 LOT:4394 BLOCK HOUSE:43" STREET:EA5TWOODS DR CITY:GRAPEVINE STATE:TX ZIP:76019 COUNTY:DALLAS ACCOUNTi:909COPTX BUILDER:COPPER STREET HOMES SUBDIVISION:CUSTOM HOMES COMMUNITY:WA PLAN:INCOMPLETE-SWNP PROGRAM:HERSI100% EFL IECC:2016 CLIMATE ZONE:3A PROPERTY OWNER: PROPERTY ADDRESS:4394 EASTWOODS DR,GRAPEVINE,TX 76019 TEST:BLOWER DOOR RESULT:PASS TESTER:Bill Beth DATE:04/14=9 TEST NAME CORRECTION BUILDER RATER WA NEEDED VERIFIED VERIFIED 5.1 Attic Access Panel(fully gasketed and insulated) X 5.2 Attic drop-down Stair(fully asketed and insulated) X 5.4 Recessed Lighting Fixtures OCAT labeled and sealed to drywall) X 5.5 Whole-house Fen[insulated Vasketed to the opening X 7.3 Fresh air ventile0on installed per program specs X Blower Door BUILDING ORIENTATION PROGRAM CODE PROGRAM CODE VOLUME CU. VOLUME CU. SHELL(SQ SHELL SQ E(90°) 41,281 0 0 PROGRAM CODE PROGRAM CODE PROGRAM CODE CFM 60 CFM 50 ACH 60 ACH 60 %of Shell %ollShell SO Tagt 0 12,064 3 BD Actual 2,057 2.99 Metier# BF152842161LGFOCS Room Pressure Test Met Bdrm 0 Oft 2 0 Bdrm 3 0 Bdrm 4 0 Bdrm 5 0 Rm 1 0 Rm 2, 0 Rm 3 0 Other 0 CO Dateotars E Star Quamed Appliances? Eftlerd Lighting P ■? 80 or>Of Hardwired Lights Must Be CFL Or LED Low Flow Faucew.Totiets etc? X Progrommabie ThennodW X Certified Green Program Level Requires Visual Inspection Mechanical em Item Location Manufaeturor Nama Model it Model 1112 Mode153 Model$4 SYSTEM 1 WATER HEATER ATTIC RINNAI UNKNOWN SYSTEM 2 WATER HEATER SYSTEM 3 WATER HEATER SYSTEM WATER HEATER SYSTEM 1 FURNACE ATTIC CARRIER 58PHB090 10120 SYSTEM HVAC OUTDOOR OUTSIDE CARRIER CA16NWOSI-8 UNIT SYSTEM HVAC INDOOR COIL ATTIC CARRIER CAPMPS024ALAAAAA SYSTEM 1 HVAC AHU (HEAT INTERIOR PUMP) SYSTEM 2 FURNACE ATTIC CARRIER 58PHB046L10112 SYSTEM HVAC OUTDOOR OUTSIDE CARRIER CA16NWDIS-A UNIT SYSTEM 2 HVAC INDOOR COIL ATTIC CARRIER CNPHP2417ALAAAAA SYSTEM HVAC AHU (HEAT PUMP) SYSTEMS FURNACE SYSTEM HVAC OUTDOOR UNIT SYSTEM 3 HVAC INDOOR COIL SYSTEM 3 HVAC AHU (HEAT PUMP) SYSTEM 4 FURNACE SYSTEM HVAC OUTDOOR UNIT SYSTEM 4 HVAC INDOOR COIL SYSTEM 4 HVAC AHU (HEAT PUMPI BUILDING SPECIFICATIONS BUILDING CHARACTERISTICS AS DESIGN-VALUES AS BUILT-VALUES COMMMENT #OF BEDROOMS(REM) NA NA CEILING FLAT(REM) NA NA SEALED ATTIC(REM) NA NA VAULTED CEILING(REM) NA NA FOUNDATION WALLS REM NA NA EXPOSED FLOOR(REM) NA NA ABOVE GRADE WALLS REM NA NA DUCT SUPPLY R-VALUE j'REM NA NA DUCT RETURN R-VALUE(REM) NA NA PROGRAMMABLE THERMOSTATS(PRIF) WATER HEATER TYPE(PRIF) WATER HEATER FUEL TYPE(PRIF) TEST:BLOWER DOOR RESULT:PASS TESTER:Bill Soft DATE 04/0212019 BUILDING SPECIFICATIONS BUILDING CHARACTERISTICS AS DESIGN-VALUES AS BUILT-VALUES COMMMENT WATER HEATER SIZE, EFFICIENCY 8 LOCATION PRIF INFILTRATION(HOUSE LKG)ACH(REM) NA Ht:2.99 Clg:2.99 ACH Q 50 Pascals FRESH AIR VENTILATION TYPE(PRIF) VENTILATION FAN MANUFACTURER(REM) NA NA VENTILATION FAN MODEL#(REM) NA NA VENTILATION FLOW REQUIRED(REM) NA NA VENTILATION EQUIP.RATED CFM REM) NA NA VENTILATION#OF FANS tREM) NA NA VENTILATION TIMER SETTING EACH FAN(REMIJ NA NA VENTILATION TIME-HRS/DAY SPECIFIED(REMI NA NA VENTILATION TIME SET BY HVAC CONTRACTOR- MINUTES PER HOUR(PRIF) FRESH AIR VENTILATION FAN WATTS(REM) NA NA MEASURED FAN WATTS OR PER MANUFACTURER'S SPEC'S(PRIF) INTERIOR%OF CFUS(PRIF) INTERIOR%OF LED'S(PRIF) INTERIOR%OF PIN-BASED IPRI EXTERIOR FIXTURES%OF CFL'S(PRIF} EXTERIOR FIXTURES%OF LED'S(PRIF) GARAGE FIXTURES%OF CFUS(PRIF) GARAGE FIXTURES%OF LED'S(PRIF) DISHWASHER(PRIF) REFRIGERATOR(PRIF) FOUNDATION TYPE(PRIF) SLAB TYPE(PRIF) SLAB AREA(PRIF) SLAB DEPTH(PRIF) SLAB FULL PERIMETER(PRIF) SLAB GRADE LPRIF} FLOW RING(PRIF) HEATING 1REM? NA NA COOLING(REM) NA NA AIR-SOURCE HP(REM) INA INA WATER HEATING(REM] INA INA Pictures,Doaun eftlon,el0 no Note Dim Photo 20190402110322.JPEG 04/02/2019 Pholo 20190402120704.JPEG 0 4/0 212 0 1 9 TEST: DUCT BLASTER RESULT:PASS TESTER:Bill Bdtz DATE 04/02I2019 TOTAL CONDITIONED FLOOR AREA 0 3,757 (CFA 80 Fr) DUCT LEAKAGE TO OUTSIDE%TARGET 0.00% 3.00% TOTAL DUCT LEAKAGE%TARGET 0.00% 4.00% SYSTEM 1 80 FT.SERVED(CFA) 0 2,711 POST CONSTRUCTION SYSTEM 1 DUCT LEAKAGE TO OUTSIDE 0 81 SYSTEM 1 DUCT LEAKAGE TO OUTSIDE 79 SYSTEM 1 DUCT LEAKAOE TO OUTSIDE Infinity% (CFM26)TARGET (CFM25)ACTUAL (%OF CFA)ACTUAL SYSTEM 1 TOTAL DUCT LEAKAGE 0 108 SYSTEM 1 TOTAL DUCT LEAKAGE 105 SYSTEM I TOTAL DUCT LEAKAGE(%OF Infinity% 3.87% (CFM26)TARGET (CFM25)ACTUAL CFA)ACTUAL SYSTEM 2 80 FT.SERVED(CFA) 0 1,046 POST CONSTRUCTION 1 SYSTEM 2 DUCT LEAKAGE TO OUTSIDE 0 31 SYSTEM 2 DUCT LEAKAGE TO OUTSIDE 28 SYSTEM 2 DUCT LEAKAGE TO OUTSIDE Infinity% -2.68% (CFM25)TARGET (OFM26)ACTUAL (%OF CFA)ACTUAL SYSTEM 2 TOTAL DUCT LEAKAGE 0 42 SYSTEM 2 TOTAL DUCT LEAKAGE 39 SYSTEM 2 TOTAL DUCT LEAKAGE(%OF Infinity% 3.73% (CFM25)TARGET (CFM25)ACTUAL CFA)ACTUAL SYSTEM 3 50 Ff.SERVED(CFA) 0 0 SYSTEM S DUCT LEAKAGE TO OUTSIDE SYSTEM 3 DUCT LEAKAGE TO OUTSIDE SYSTEM 3 DUCT LEAKAGE TO OUTSIDE (CFM25)TARGET 0 0 (CFM25)ACTUAL (96 OF CFA)ACTUAL • TEST:DUCT BLASTER RESULT:PASS TESTER:SM Beth DATE:04102=9 SYSTEM 3 TOTAL DUCT LEAKAGE 0 + 0 SYSTEM 3 TOTAL DUCT LEAKAGE SYSTEM 3 TOTAL DUCT LEAKAGE(%OF (CFM25)TARGET (CFM26)ACTUAL CM ACTUAL SYSTEM 4 SQ FT.SERVED(CFA) D 0 SYSTEM 4 DUCT LEAKAGE TO OUTSIDE 0 0 SYSTEM 4 DUCT LEAKAGE TO OUTSIDE SYSTEM 4 DUCT LEAKAGE TO OUTSIDE (CFM25)TARGET (CFM26)ACTUAL (%OF CFA)ACTUAL SYSTEM 4 TOTAL DUCT LEAKAGE SYSTEM 4 TOTAL DUCT LEAKAGE SYSTEM 4 TOTAL DUCT LEAKAGE(%OF (CFM26)TARGET 0 0 (CFM26)ACTUAL CFA)ACTUAL BUILDING SPECIFICATIONS BUILDING CHARACTERISTICS AS DESIGN•VALUES AS BUILT-VALUES COMMMENT DUCT LEAKAGE TO OUTSIDE(REM) INA 0.029 CFM26/CFA TOTAL DUCT LEAKAGE iREMi INA 0.039 CFM25/CFA FLOW RING(PRIF Piclums,Doa mentdon,etc FDe NCO Deb Photo 20190402113034.JPEG 0410212019 Photo 20190402112856.JPEG W0212019 Photo 20190402111755.JPEG 04/02/2019 Photo 20190402111747.JPEG 0 4102/2 0 1 9 Photo 20190402111538.JPEG W02/2019 Photo 20190402113026.JPEG 04/02/2019 Build TopBuild Home Services, Inc. — Performance Testing Certification TopBuild Home Services, Inc.has conducted BPI and/or RESNET/HERS testing an the following property. The information and results are outlined below. (Note:This document does not certify compliance with the entirety of the 2015 IECC,It certifies the results of the performance testing only). Builder.Copper Street Homes Subdivision:Custom Homes Property Owner: Total Conditioned Floor Area: 3,757 ft 2 Permit Date/No.: Conditioned Volume: 41,281 ft3 IECC Version: 2015 Property Address: 4394 Eastwoods Dr, Grapevine,TX 75019 Testing Performed 2016 IECC(Sec.402.4.1.2—Testing Air Leakage)Blower Door Test 04/02/2019 Measured Air Leakage: 2057 CFM @50Pa Result: PASS Air Infiltration: 2.99 Confirmed ACH ACH 50 Targets 3 2015 IECC(Sec.403.2.2—Testing Dud Leakage)Dud Blaster Test 04/02/2019 System 1 Duct Leakage. 105 CFM @25Pa Result: PASS Confirmed Leakage: 3,87% DL%Target<_4,00% Phase Post Construction CFA:2,711 ft2 System 2 Duct Leakage: 39 CFM @25Pa Result: PASS Confirmed Leakage: 3.73% DL%Target<_4.00% Phase Post Construction CFA: 1,046 ft 2 System 3 Duct Leakage: NIA Result. NIA Confirmed Leakage: NIA DL % Targets NIA Phase NIA NIA Digitally signed by Bill Belitz Date:2019.04.18 18:28:17 EDT Rater Of Record: CN=Bill Belitz,O=TopBuild RESNET#:6840203 Home Services,OU, E MAILAD DRESS=bill.belitz@to 04/02/2019 pbuild.com,C=uS BPI Certification#: N/A Thank you for allowing TopBuild Home Seraices,Inc.the opportunity to provide the above services for you.Please feel free to contact me with any questions. Sincerely, p4 Bill Belitz CPU:410-56C}7390 p't , O � y bill.belitz@topbuild.cam 4� f� 475 N Williamson Blvd.Daytona Beach,Fl-32114(866)912-7233 iN0.''f�9a089 1��7{ This form was from EFL g�property oP Qq�oiTAd 1�N generated Prc�jed Mane of T 8uild Home Services,Inc, ,,,,,a- 423845 Then for Final check after plaster you will have$3544.50 plus cost of gas line and the cost of the Mini dolphins Any questions just let me know Greg Heisel Patriot Pools 2 Mark Cooper From: Sent: Thursday,April 18, 2019 5:28 PM To: Jason Drew, Mark Cooper Subject: Test Results.CUSTOM HOMES. L4394 Attachments: Test Results. CUSTOM HOMES. L4394.pdf, IECC 2015.pdf, Photo_20190402110322.1PEG LOT: 4394 ADDRESS: 4394 EASTWOODS DR, GRAPEVINE, TX 75019 BLOWER DOOR- PASS DUCT BLASTER- PASS ACCOUNT M 909COPTX BUILDER NAME: COPPER STREET HOMES SUBDIVISION: CUSTOM HOMES COMMUNITY: N/A PLAN NAME: INCOMPLETE-SWNP PROGRAM: HERS1100% - N/A TESTING FREQUENCY: EACH (PLUS) SITE ID:423845. i