Loading...
HomeMy WebLinkAboutRMISC2017-2932 * - zV * 0 ., Ti �`-' DATE OF ISSUANM G 2 8 2017 br e t .1s W l PERMIT#• 1 3 BUILDING PERMIT APPLICATION (PLEASE£ASI Ylii ? LEGIBLY—Cf)11PI_i:T ENTIREi%OI2`i) JOB ADDRESS: 2 a 7 T��b�� s'��� SUITE# LOT: BLOCK:_ SUBDIVISION: Lc te-5 i`4- ES r-+-,r-S BUILDING CONTRACTOR(company name): �t p�15 k ��c)-oo r (, CURRENT MAILING ADDRESS: PO Dox Z CITY/STATE/ZIP: SO(AAA WCAL 1 1L 7(e 0 g 2 PH:# $17-3 19-Z?SSA Fax# PROPERTY OWNER: p-CA)14 CURRENT MAILING ADDRESS: Z7 O 7 CITY/STATE/ZIP: C7(ztp�tr,yLL �jL 7 e O S l PHONE NUMBER: S 1 )- &So- o 30 G PROJECT VALUE: $ Z S,U 6 0 FIRE SPRINKLERED? YES NO_A WHAT TRADES WILL BE NEEDED?(Cheri;clues wat appiv)ELECTRIC PLUMBING X MECHANICAL DESCRIPTION OF WORK TO BE DONE:.- ��t c� 'f v+5 ..S s4iti..� l '� USE OF BUILDING OR STRUCTURE: P2,C5 ov-0— n w t b NAME OF BUSINESS: _ Total Square Footage under roof:_ f(� Square Footage of alteration/addition: _ I hereby certify that plans have been reviewed and the building will be inspected by a certified energy code inspector in accordance with State Law. Plan review and inspection documentation shall be made available to the Building Department(required for new buildings, alterations and additions) ❑ I hereby certify that plans have been submitted to the Texas Department of Licensing and Regulation for Accessibility Review, Control Number: (Not required for 1&2 family dwellings) ❑ I hereby certify that an asbestos survey has been conducted for this structure in accordance with the regulatory requirements of the Texas Department of Health. (REQUIRED FOR DEMOLITIONS,ADDITIONS AND OR ALTERATION TO COMMERCIAL AND PUBLIC BUILDINGS) I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by the Building Department and in compliance with the City Of Grapevine Ordinance regulating construction. It is understood that the issuance of this permit does not grant or authorize any violation of any code or ordinance of the City Of Grapevine. 1 FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY,AND THAT THE DESIGN PROFESSIONALIOWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROVAL FROM T13E APPROPRIATE STATE AND OR FEDERAL AGENCY(S). PRINT NAME: 4S0nJ Cry Tr-- SIGNATURE _— PHONE#: 319 EMAIL: ❑ CHECK BOX;IF PREFERRED TO BE CON TED BIL THE FOLLOWING IS TO BE COMPLETED BY THE BUILDING INSPECTION DEPARTMENT Construction T )3 Permit Valuation: $-?9 ac>t) 'vb Setbacks A roval to Issue Occ ancy Gro : l�•3 Fire Sprinkler: YES NO — Front: 10 t Electrical t� Division: Building Depth: 31 Left: 6► Plumb in i' Zonin : R. 7'S Building Width: 3 1 Rear: 7. 1 Mechanical — OMUPaRcyLoad: Ri t: 1 1 Plan Review Approval: Date: '9 10 1 Building Permit Fee: Site Plan A roval: Date: Plan Review Fee: Fire D artment: Date: Lot Drama e Fee: Public Works De nrtment: Date: Sewer Availability Rate: Health De artment: Date: Water Availability Rate: Approved for Permit: Date: g Zq•1`1 Total Fees: of Drainage Submitted: P, Approved: $ •j l l-11 Total Amount Due: •, P.a.BOX 951Ua,GRAPFtMwF-nc7sog(W)410-3165 O;FOR swsrERUrAPPuCAnoNSIAMA ,.11104,6MsbW,Iiroe,41 [rr, BUILDING RESIDENTIAL ACC STRUCTURES Issue Date:August 28,2017 � 7 E A A PROJECT DESCRIPTION:Outdoor Living Structure 13'X 13' PROJECT# (817)410-3010 WWW.mygov.us RMISC-17-2932 Inspections Permits City of Grapevine - - — - — - - LOCATION LEGAL Grapevine,,T TX 76099 P.O.Box 2707 Pebble Stone Lakeside Estates Three Blk 1 Lot 1 X (817)410-3165 Voice Grapevine,TX 76051 *07174667* (817)410-3012 Fax CONTRACTOR INFORMATION Elite Pools&Outdoor Living *CONSTRUCTION TYPE VB P.O.Box 93562 *OCCUPANCY GROUP R-3/U Southlake,TX 76092 *ZONING DISTRICT R-7.5 (817)319-2758 Phone **APPLICANT NAME Jason Cate (817)319-2758 Mobile **APPLICANT PHONE NUMBER 817-319-2758 APPROVED TO ISSUE ELECTRIC YES OWNER APPROVED TO ISSUE MECHANICAL NO Aaron Kutch APPROVED TO ISSUE PLUMBING YES 2707 Pebble Stone Grapevine,TX 76051-2412 County Tarrant Fire Sprinkler System? N/A AVAILABLE INSPECTIONS Square Footage 169 Building Foundation/Footing(required) VALUATION 28000 ► Building Pier(required) Building Setback(required) FEES TOTAL=$376.75 Building Framing(required) r Lot Drainage Inspection(required) Building Permit Fee $376.75 Building Final(required) PAYMENTS TOTAL=$376.75 Elite Pools&Outdoor Living(Jason Cate) Check on 0812812017 ($376.75) Note:CK#001262 NOTICES 1)ALL work must be done in compliance with the 2006 INTERNATIONAL BUILDING CODE. 2)A copy of the signed permit and approved plans must be on site at all times. 3)The project address must be clearly posted at the job site. READ AND SIGN I hereby certify that the foregoing is correct to the best of my knowledge and all work will be performed according to the documents approved by the Building Department and in compliance with the City of Grapevine Ordinance regulating construction. It is understood that the issuance of this permit does not grant or authorize any violation of any code or ordinance of the City of Grapevine.I FURTHERMORE UNDERSTAND THAT PLANS AND SPECIFICATIONS ARE NOT REVIEWED FOR HANDICAPPED ACCESSIBILITY BY THE CITY,AND THAT THE DESIGN PROFESSIONAL/OWNER IS RESPONSIBLE FOR OBTAINING SUCH APPROVAL FROM THE APPROPRIATE STATE AND OR FEDERAL AGENCY(S). MYGOV.US City of Grapevine I BUILDING RESIDENTIAL ACC STRUCTURES I RMISC-17-2932 I Printed 08/28/17 at 4:05 p.m. Page 1 of 3 Sigh attire Date l j MYGOV.US City of Grapevine I BUILDING RESIDENTIAL ACC STRUCTURES RMISC-17-2932 I Printed 08/28117 at 4:05 p.m. Page 2 of 3 A=-- LL IT rl PL4AI PT AT S H 0 NIMN, G I EROSION CONTROL REQUIRED BEFORE CONSTRUCTION STARTS. 2. NO CONSTRUCTION, FILLING, CUTTING, OR GRADE CHANGE IN EASEMENT WITHOUT PRIOR APPROVAL. 3. MAINTAIN CURRENT DRAINAGE PATTERN. 4. GRASS/EROSION CONTROL REQUIRED BEFORE FINAL. 7" 707 9- Lq Zc:) 0 -j LLJ Ul LL() cad u Z Z z > LO 0< 0 z 15 cc Z z cr 0 0 0 < L LLJ LZ 3�,�FZ= o z U0 �c") L) S02 CO z 0 ti 0 LL, :ij I g�- '9 yy 0 < L) L, c w Q- n- La. OZ CL Lui �--.3 7 OZ w OZ con LU 3nLU Z uj • MC zI uj cn LU l { �i fro 'X T E 1 A N ' June 17, 2019 Elite Pools & Outdoor Living 2701 Lonesome Dove Road Southlake, TX 76051 RE: EXPIRED PERMITS, 2707 Pebble Stone, 17-2933 & 17-2933 Dear Applicant: Our records indicate that your company has taken out permits that have expired and have not been finaled. Failure to begin work within 180 days after permit issuance or allowing 180 days to pass between inspections will result in an expired permit. Once a permit has expired, the permit must be renewed and new fees paid. Permits which have expired for more than 30 days are subject to the issuance of citations. No future ermits will be issued until the contractor resolves all expired Permits. In order to reinstate your registration, Your expire I Dermits must be re- instated and obtain final inspection. Enclosed is a copy of the permits issue' to your company which have expired. PostalN 0 m Er Domestic mail Only c o Sincerely, o 3 ru p O Ir SD � o_ Certified Mail Fee (D N a - X4 0 90 �- $ Connie Cook r-a Extra Services&Fees(check box,add fee as appropriate) O ❑Retum Receipt(hardcopy) $ Development Services Assistant ❑RelumRecelpt(electronfc) $ CD ❑Certified Mail Restricted Delivery $ 0 []Adult Signature Required $ ❑Adult Signature Restricted Delivery$ ol O C3 Postage < 1 o $ r- IO Total Postage and Fees r1 $ r%- Sent To Q= Development Se C3 StreetandApL No.,or PO Box No. `` The City of Grapevine P.O.Box 95104 -' ci67 state;ziP+d------------------------------------------- Fax(817)410-30 Y) Manda Pancholy From: Manda Pancholy Sent: Thursday, August 10, 2017 9:29 AM To: ' Subject: 17-2932 2707 Pebble Stone (Detached patio cover) Jason Cate, In reference to above permit please provide required information in two hard copies in response to following comments. Comments: Patio dimensions shall be consistent on engineered plan and site plan. Show all existing and new structure including fireplace on the site plan and labeled setbacks accordingly. Footprint on the floor plan and site plan does not match. Detached patio shall be setback minimum 10'from any structure on the lot. Plan shows fireplace chimney by others, engineered detail requires rafters and beam to be nailed into chimney stud. Fireplace chimney requires building permit. Provide electrical and plumbing details. Manda Pancholy Plans Examiner City of Grapevine 817-410-3160 1 MOO jo z Z W ll V OQ z > ..I z o } O ro p z� a 4,�47,m ... ....:_, '' � •r�`}'-�`.r( '�, !mil +.7 � vj � }Z W _� �OZ F- Q Z Ln 11 1 a r , ti ¢w C ca -_� t!) + ¢O � o .. o L1. oo aW z° co w W wm ~ � mo15 Z CO o= ,� Q L _ Q LU �_ w W 2 LUuj l ti i�i �z VL �> a r a; co -44 44 ,C?{ (41 it ht t Zo • N Q �•t1Q��Lea-�' �' ' � . q b ��� 11 • '-L�vs� �....�.�--,i_.�:-� r �. pq a d -c1-i�S PE.QM�'� �S dNl-y �pf2 1'��Tf3 �HG-J PA"�fa EEPARATEPLLUWA&GCKMWA1.v &GCKM RgGTWALAND SM PEA Pool Depth Profile SH"BE REQUIRED 91 ® -- aft.6in. - 6ft. 5ft.6in. L O e — 22ft.An. 4ft.101n. I 1,511�►I r � Water Features CONT ACTOR SHALL CALL FOR Size:26'x12' Sg Ft:265' N S P EC 1 I O N J, Depth: 3'6"x 5'x 4" Perimeter:67' 49, Est Total Gallons:.8000 Spillway:NA 1 ly) 410-301 0 Raised Height:NA Skimmers:1 A Returns:4 Tile: Standard 6" Ox CON i RACTOR REGISTRATION Interior Material: Pebble to be Selected 7 D' WIt.L. BE REVOKED UPON Special:2 Bubblers on Tannin Ledge/2 Spray heads on back wall in tile line. O - ERMIT EXPIRATION. Notes: Hardscapes Deck Type: Stamp-one color Elevation:2'below foundation `^ ALL CHANGES REQUIRE Total Deck Sg Ft:720 Perimeter: APPROVALRaised Beam: NA Lip Style: OF REVISED PLANS Material 1: ConcreteStamp 1 color _ Material 2: - Special: Existing Deck will have a cool deck overlay spray applied. APPOVED PLANS SHALL BE Notes:Retaining walls will be chopped Oklahoma builders stone KEPT N JOBSITE ATALL TIMES CITY OF GRAPEVINIE FIMSED FOR CONSTRUCTION EET OFF EASE DOES NOT AUTHORIZE ANY WORK IN CONFLICT ' WITH THE BUILDING CODE OR ZONING ORDINANCE. ` - - - THIS PLAN TO BE lit TON THE.SOB AT AILL TIME�s�//� i BUILDING INSPECTION DMSION ` RELEASE DOES NOT APPLY TO CONSTRUCTION N EASEMENTS OR PUBLIC RIGHT-OF WAY. Change Orders CD# Description Date PO Box 93562 Customer Info _ Southlake, Texas 76092 Name: Dina Kutch I have reviewed and I give my approval to proceed with the Designed by: Jason Cate Address:2707 Pebble Stone construction of this project. Office: 817-481-3607 City:Gra:,evine State:Texas Zip:76051 Cell: 817-319-2758 Home Phone: Mobile:817-680-0306 Work Phone: f Customer Date OFFICE COPY Y STRUCTURAL GENERAL NOTES FOIMDATlOM4 L FOUADATIONDESIGNASSLMfS A NIANUMBEARRECAPACI rY OF 600 PSF,CLASS S GENERAL REQU/AfNENTS: 2.SLAB-ON-GRADECONSTRNCTIONSHALL BESUPPORTMONSUBGRADECOMPACTEO WA !STRUCTURAL DRAWIADS SHALL BE USED INfON/UVCTIONWITH THE SPEURCATIONY ANT OTAS DENSITYW HOLfSS THAN 95X OF TW MMRED PROCMR NAXMMDRYDENSI rYMSTH P9OKCTDRAWIN0BYOTHEROI5C/PlMVS ALL WORKSHALL EVIOWN TO THEREQXREMENTSOF D-6571 TOADEPTNOPATLEAST f2lKWES. INf CODES LISTED BELOW 3.SHALLOW A010ATIONS DO AOraffi0M TE DEPOrENDAL FORNOVEMENrIN TNfLOAG PROJECT LAKEPARKOR fZ'-3 W2' 2.CON7RAC70RSHALL VERIFYALL NMENS'IONSAAVELEVATIONSRELA71AG 70EXISTOW rERK IFaIENTOOESNOTArriPr r1EP0ranAL FORMOV90VTOFAPPROXIMATELYI{' LOCATON LTMtlITIOAS BYNAKINGRfLDSURVEMANDMEASLWMNTSPRRLR TOCOMAiKIADFABRICATIONOR TNfNPIERSAMA GEOTECMWCAL INVESRGATIONMAYBfREQIRRM.. CAADPY r6" EDISONKrroK IB'XfB•X>g" 3.rNfiEArERAICONTRACTORSNALL COMPAREANOCOOROINATE OB'DRAW/AGSOFALLDISOPLIIES CAST-IN-PLACf[ONKRE>E PROJECT FOOMNGS AND REPORT ANYDISCREPA/KIES BETWEEN THEORAWN0 TO TIKARCNrfCT AAO aVALER. I TNELATEST fUTTONOf THEFOLLOW/AGACl S7ANDAROS APPLY, LOCATION TYP.4 4.DETARSLABEEM'TYPICAL'SHALL APH Y TOALL SIMATNNS TNATARE THE SAAWOR SIMILAR A03f8/CODDAC1304(PCACIAW POOL b TOT/IOSESPECIACALLYDETABEA SEEDFTAU 71RESFDRAPPLICABIL/TYOFAPAR17CULAR AC3MfWlMYPtOACRET#4AD36(DErAIL/AS DETAIL.TYPICAL D£rABSSNALL APPLYWHETNERORAror TNEYARESPECOCALLYKEYMATEMN AV 30S(HOT WfA PER CONCRETING)AD 3471FORMWORK) LOCAMN.THEEA01NEIRSHALL HAVERNAL AUTNO,WTY TQOETERNNEAPPLKABBITYOF TYPICAL AC1 Zft.fLMXPRWORTIOMADl AO30flSPMIFKATIONS) w� DETAILS \ 2.ALL COAKRETESNALL Bf NORMAL WRGHTl98PCFDRYDEASITY,NIN,WITHNXESDESIGN£D ` EXLSrINGSUME >QMEETAMMLM/MOF3000PSI2B-DAYCWIPRESSIVESTRD67H UNL£SSOYft WS£NOTED. I /� STORY SPECIAL INSPECTIONS: `c Ya P t`4 s n e 3 A CONCRETENX DfSIGNFOR EACH UMQUE COMMA MW OFSTREADTK COARSE AG NSATf ; I RfSCEMKE i IAV SPECIAL INSPECT/ONISREONRED,VERIFY WITH CITY Of SSa POW FOR SPECIAL WSPEC7WN GRADA I/ON AHD WA TER C969 RATIO SPECIRED SHALL BE PREPARED BY DE SUPPLIER OR 5 REQUIREMENTS ANIADEPEWNT 7FS7006LABORA TOR YAND of SUBNrrFO FOR REVIEW PRIOR ToCASTOO ANY CONCRETE.NXES THAT Wit BE IRA NSPORTED AT THE PROJECTSIIFBY PUMPW SHALL Ian CON6TRUCTlONRESPONSINLITY+ BESPECIRCALL YDESGMOFOR POIW06. f„ L TNECONIRA[TSTRIIC7IIRAL DRAWINGS AND SPECIRCATIONFREPRESENT TIE COMPLETED A _ _ k S7RUCTUR&ANDAREA07IMENDED TOIMKArf TMEICr OORMEAA50FCDNSMVCMX PE RRNFORCIAUSTEa, CONTRACTOR SHALL SUPERVISEAND DIRECT MEWDIW AND SHALL BE I REINFOROMS STEEL.ASTM A 6$GRADE 60. SOLELYRESPONSLfFOR ALL COAUMLC71ONNfAKL ETIDDS,PROCEDWES;7ECM000ES 3111NMUNREO90RCINGSTfEL CLEAR COVER(OHQ1: d'6• SEDLENCES AND FOR"SAFETY. A.COACRETECAST DIRECTLY AGAINCrEARTH..3' PROJECT L OCA TION 2 DEEAVABERDOESNOTHAVECOMM ORCHAWOFAW SHALL NOTBERfSPGRS'IBLEFOR &INTERIOR SLABS....„................r Mrs.. CON57RUCTIOMNEAAIS,HfIN005,TfCHATQUfSSEQUENCESWRPROCEDURESfORSAffrY C.INTERIOR BEAMS.......................f-V2'TO TIES PRMAUTIOASAADPROGRA16NMWECTONW17Hr&WORK FORMEA177SOROMSSMSaFUE D.SLABSORGRAD£......-..-...........r-W2•FROH TOP CDNTRACTog SUBCONTRACTOR,OR ANY 07M:R PERSOMPERFORNAGANY UP THEW4%ORFOR 4,WHERfREINMRCING BARS ARENOTED ASCONFIRUWS,THEAMLOWINGSHALL BECONPLIED TNBFAILMEOFANYOF THEN 7o CARRYOUr THEWORKWACCOROAACEWITH TIECONTRACT WITH, DOCUNfNM A.THE WMATIONOFALL CONTINUOUS RfNFORCIAO BAR RUW SHALL REA STANDARD MDOK q UNESS NOTED 07HERMSE. 9 PRIMARY[OOE5 AND SPEDR[AT10A5r B.SPLICES UIMMNUOUS BOTTOM BARS lFREQUIRED,SHALL OCCUR OVER Cm WALLS OR L GENERAL BUBDOG COW, CENTERED OVER COLUMNS. 00, A.INTERNATIONAL RESMIZAL C S FERNANDO PENA•• n 7 DOE;2006 S WHERE LENGTHS ARE SPEC/RfO,USE BAR MASDAEPY AND 60 4•••ti•• r1�V� non ram, w Z.COMM CODES, BAR O/AMF7ER5lNCASTCOAKR£I£. 706233 ��jj _ll f l/`�r L+ OUTDOOR A SPEC/FKATONS FOR STRUA,BUILOLAU CODE CTURTS ALCWBRETEFOR B STRUCTURAL �i�STE r(AO3911. STER SSMIIESARE NOT PERNrrEO TACK WELDED FOR ANY REA50N WELDED REINfOA[ING ylll RELEAED FOR CONSTRUCTION Y aSTWn4R�«">� M4IADAL Of STANOAAO PRACTKFW/iJ1AlL SUPPLEMENTS STRUCTURAL WODO D7IOW,7 PLAN VIEW A.SPECIRCATIONFOR STAUCRMAL STM SMOIN6S,fAISC360-OSA 1 ALL WOOD IONERS SHALL HE WESTERN RED CEDAR MADE MARKED BY A RECOGNIZED L .rW 6.HA5ONRYCWSTRUCTOk 6RADINGAGE7KY SHEET. OF. CANOPY AND OUTDOORCNNB•YADUADA7ION 7.WOW CONsmorTON 2.PLYWOOD SHALL BE APA RATED SHEATNAS AND SHALL CONORM 70 COMMERCIAL PRODUCTS A.NATIONAL DESIGN SPECIRCA TION FOR WOOD CONSTRLBRON(NDS-OS). STAN7ARDSPSZ-97WHEREREQUIRM.. RELEASED S NOT AUTHORIZE ANY WORK IN CONFLICT 3CUTRArl MACAM09DRALINGOf&EAMSORARSTS SHALL BEPERN AS TTEDOKYAS ALLDOOMI ARfAPPROXINATf REFER M DESIMIOAPP OETABEDORAPPROYMBY THE EMWAE£R AAD/OR PER/BCAPPLICABLESECrION1 ARCHIECTURAL ANO/OR FIELD VERIFYADR WITH THE BUILDING SIDE OR ZONING ORDINANCE. I.ROOFLIVELOADS, 4.ALL NABINGSHALL CONFORM 70 MC TABLES FXACrLOCA7ONAW DIMENSIOA5. p� •rye A UNFORK YDS7RroUrM L1VfLOAD ONHQNZONTAL PROJECTION....................20 PSF 5 BOL IS IN WOOD SHALL ACTB£LESS THAN 7 DIAMETERS MN TIE END AND 4 DIAMETERS PLA N AN TO BE KEPT ON 2.WIND LOADS, FROM THfoodc TI NIfilfo. A LDADS BASED ONASCf 7-05 WOW LOAD CRITERIA. 6.ALL RRAMAUM-I DRS FoSrCAPS BASES HANGERS STRAPS,Err,SHALL B£AS THE JOB ATALL TIMES BASIC WOD SPEED 3SECOM DUST......„...„......00 MPH NANIFACTURFOBYSINPSONCOMPANYOR APPROVED EQUAL. WIND B(POSURECAWCORY.........................B 7.MOISTURECONI£Nr OF WOW AT 7NB•OF PLACING SHALL NOT EXCEED ON DATE:DA ' S'1l BY. �^ WIND wFoORAPNKFAC70R KIT.........„....„......t0 6 G UILDING INSPECTION DIVISION RELEASE DOES NOT APPLY TO CONSTRUCTION IN CHI"N S'l -� 0-T%A'E R.5 12 S Q U I Q-SD P CE R M I-1 13 E'FO 12E C)i 1 to l4 El COr1S" R O LA 1 d�I EAS•MENTS OR PUBLIC RIGHT-OF-WAYS--_____—, REV DATE I REVISION ORW CHK APP L E P V I RAFT�RS�68"&C.MAX. US£V4'LAGSCREWS CLIENT I RAFTERS —a r-----� BEANS INJOCIIlMNfY 2X6 ELITE POOLS AND SW WALL FRAMAO CEDAR ROORNO PER RODRNG ?1''B 1RUSS OUTDOOR LIVING I MAMFACIUMS PER CEDAR RDGE WED SPE[1RCATlONS NAMIFACTIONS �ROGI(y SUMMIT I15E TWO f/4'LA6S[REWS � i SPfClF7CAT10N5 3/45NEA7YIMGBOAIPO All 2X8 . sNNGLERoaF CEDAR RAFTERS ENGINEERING CONSULTING,LLC. I ' 4Xf2 _ CEDAR a _ I BOTTOM I 15,-2 f12• BXg I CHORD TBPE FIRM#:14437 B'-7112' —US£FOUR3/&•LAG CEDAR R NN3•INrO P7YA4 I PROJECT cmlhw L I I /STAGGER 70 AVWD a I INTERSECTIONj 2707 PEBBLESTONE OUTDOOR 4 I I 4XI2 I I CNNVfY SIN'SON CEDAR 7BYBASE I I BEANS LOCATION FFL OTHERS! BRAOXET 1 I 3X3 CEDAR GRAPEVINE, al7arF TX WIWOR 6"X6•XfB• —T—^--'— '" CIINEY DRAWING TITLE: OTNNG 72•X53•XfB" 61i 1114'EACNWAY COMAEFE 3I3 EacHWar rov _ PROPOSED CANOPY A1leorrav -- AND POOL ADDITION CONCRETE TOP AADBOTTOFI FOOTING ISOMETRIC VIEW FRONT ELEVATION SCA —17;Y-0' CA NOP Y FAA FOUNDATION AND FRAMING SCALE : - NNG SIDE&EVAV-ATIO Drawn Data Cheek. Date App. Date MIX 07106117 FPRE 07/06M7 FPRE 07/00/17 C _1 Pro/eot Number SCALE Dwg Sheet Size Fo o ► l D A-i )n K) ) 5 E Gam)O N ),S Q E 0296 AS NOTED D q U fej L Drawing No. REV PEB-S-1